CMU Fire Rating Chart
Ernest Maier CMU Complying with the 2014 Edition of the ACI/TMS 216.1
Equivalent Thickness Table 6.0 – Tek Note 7.01D
Fire Resistance | Nominal Size | ASTM | Solid Materials | Equivalent Thickness (in) |
½ Hour | 2x8x16
3x8x16* |
C-145
C-90 |
100% 73% |
1.9 1.9 |
¾ Hour | 4x8x16
3x8x16 |
C-90
C-145 |
65% 100% |
2.4 2.6 |
1 Hour | 4x8x16
4x8x12 4x8x16* |
C-90
C-90 C-145 |
73% 73% 78% |
2.7 2.7 2.8 |
1 ½ Hours | 6x8x16
8x8x16 Normal Weight |
C-90
C-90 |
54% 50% |
3.0 3.8 |
2 Hours | 2-1/4×3-3/4×8**
4x8x16 4x8x12 8x8x24*** 6x8x16*** 8x8x16 Medium and Light Weight*** |
C-55
C-145 C-145 C-90 C-90 C-90 |
100% 100% 100% 52% 64% 50% |
3.6 3.6 3.6 3.7 3.6 3.8 |
3 Hours | 8x8x16
10x8x16 |
C-90
C-90 |
63% 50% |
4.8 4.8 |
4 Hours | 8x8x16
8x8x12 12x8x12*** 12x8x16 6x8x16 8x8x12 8x8x16 |
C-145
C-145 C-90 C-90 C-145 C-145 C-145 |
75% 75% 55% 50% 100% 100% 100% |
5.7 5.7 5.4 5.6 5.6 7.6 7.6 |
The 2014 edition of the ACI/TMS 216.1 is referenced by the 2015 and 2018 IBC for concrete and masonry materials
* BMS 92 – National Bureau Standard
***Above Blocks Plastered on One Side with 1/2 inch 1:3 Gypsum and Sand Plaster adds 1/2 Hour to Fire Rating
Primary Aggregates – Expanded Shale and/or Pumice
VP of MasonryTed Kelly
Latest News
4 Ways To Reinforce Concrete
Concrete is one of the most fundamental materials used in construction. If you’re working on a domestic project or a […]
The Environmental Benefits Of Using Ready-Mix Concrete
The construction industry is changing quickly to meet the growing demand for sustainability and eco-friendly practices. One of the most […]
6 Essential Tips For Grouting Stone Veneer
Grouting stone veneer is an important step in the installation process that can significantly impact the overall look and durability […]
Should You Fill Hollow Concrete Blocks?
Hollow concrete blocks are widely used in construction due to their strength, versatility, and lighter weight compared to solid blocks. […]